Export wireless heat detection resource

Wireless Heat Alarms for School Facilities: OEM Guide

Plan export wireless standalone heat detection for school facilities and oem decisions, with WANLIN-340 evidence, network checks and radio-scope boundaries.

Direct answer

What is a standalone heat detector?

A standalone heat detector monitors temperature and provides a local audible and visual warning when its defined alarm condition is reached, without requiring a conventional fire alarm control panel. It should be selected where the fire strategy and normal environment support heat detection.

Heat detection does not replace smoke detection automatically. A qualified project review should decide the detector type and placement for each space.

WANLIN-340 standalone heat detector

Documented model

WANLIN-340: verify the configuration before ordering

The supplied Ver 1.0 manual documents a WANLIN-340 temperature-sensing alarm and describes an NB-IoT reporting module. This does not prove that every WANLIN-340 SKU contains the same radio, platform or evidence scope.

Read the WANLIN-340 user manual · Review the evidence center

Verified manual data

WANLIN-340 documented configuration

Evidence scope: User manual Ver 1.0. Values apply to the documented configuration only. The listed standards are manual statements, not third-party certification claims.

Parameters transcribed from the WANLIN-340 user manual
Detection principleTemperature sensing with MCU processing
Detector classificationClass AS; point-type, fixed-temperature alarm in type-test report Dz2023201944
Rated working voltageDC 3 V
Battery capacity2400 mAh
Standby current≤ 6 μA
Alarm current≤ 100 mA
Sound pressure45-75 dB at 3 m directly in front, as stated in the manual
Operating temperature0 °C to +55 °C
Relative humidity≤ 95% RH at 40 °C ± 2 °C
Alarm outputAudible and visual alarm
Low-voltage thresholdBelow 2.7 V
Normal indicator intervalAbout 50 s
Low-battery chirp interval50 s ± 1 s
Silence periodAbout 80 s
Dimensions100 mm diameter × 47.3 mm
Approximate weight140 g including battery
Manual-listed execution standardGB 30122-2013
Installation referenceGB 50116-2013; project design requirements govern final layout

Model-matched test evidence

What does type-test report Dz2023201944 support?

Identity and scope

Shenyang Fire Research Institute, Ministry of Emergency Management issued a type test report (not a product certification certificate) for model WANLIN-340. The report lists 14 samples and a test period of 2023-09-26 to 2023-12-04.

Test basis and conclusion

The stated basis is GB 30122-2013 and GB 12978-2003 inspection rules. The report concludes: All applicable GB 30122-2013 items tested in the report were judged compliant.

Measured results

Two action-temperature results shown are 58.5 °C and 58.3 °C. Initial sound-pressure results for 14 samples range from 70.5 to 72.5 dB. These are report measurements, not guaranteed values for every production unit.

Evidence boundary: the report is dated 2023-12-07 and identifies a Class AS, point-type fixed-temperature alarm. It does not by itself prove that every radio or cloud variant has identical construction, nor does it constitute destination-market approval.

Marketing-material reconciliation: a supplied promotional image states an alarm-action upper limit of 65 °C. That is kept separate from the report's measured sample results of 58.3-58.5 °C and from the manual's operating-temperature range of 0-55 °C.

Wireless export architecture

What must be confirmed for a wireless WANLIN-340 project?

Detector and radio configuration

Freeze the exact detector SKU/BOM, radio module, frequency band, antenna arrangement, SIM or gateway dependency and firmware revision. A family name alone is not sufficient.

Platform and alarm workflow

Define what happens locally, what is transmitted, the receiving platform, account ownership, notification path, outage behaviour, data retention and the party responsible for response.

Destination-market evidence

Match product fire-detection evidence and radio or telecom evidence separately to the exact configuration, legal holder, destination country and current validity period.

Documented boundary: manual Ver 1.0 states that an NB-IoT module sends data and that third parties operate associated IoT platform services. Type-test report Dz2023201944 evaluates the heat alarm against GB 30122-2013; it is not represented as NB-IoT, LoRa, 4G, 433 MHz, telecom or destination-market radio approval.

Where does the manual suggest heat detection?

Challenging smoke environments

The manual lists places with dust, retained smoke or vapour, and rooms where smoke detection may be unsuitable. A project review must still confirm detector type and environmental limits.

Potential non-smouldering fires

The manual identifies locations where a fire may develop without an early smoke signature. The project fire strategy should define whether fixed-temperature, rate-of-rise or another method is required.

Application review

Kitchens, boiler rooms, generator rooms and drying workshops are examples in the manual. Local design rules, spacing and commissioning requirements remain controlling.

For Wireless Alarm and Strobe Devices for Warehouses, begin with the expected normal temperature, nuisance conditions and the fire scenario rather than selecting by radio name alone.

Export specification checklist

  1. Destination country and applicable requirements
  2. Exact WANLIN-340 SKU/BOM and sensing behaviour
  3. Normal and abnormal ambient conditions
  4. Local-only or remote reporting architecture
  5. Power, label, manual and packaging language
  6. Model-matched certificate or test evidence

Answers for buyers

Standalone heat detector questions

When is a heat detector considered instead of a smoke alarm?

A heat detector may be considered where normal dust, vapour or smoke can make smoke sensing unsuitable. Selection must follow the fire strategy, local rules and the actual environmental limits of the chosen configuration.

What must be checked before installation?

Check detector type, spacing and coverage design, ambient temperature, nuisance conditions, mounting position, maintenance access and applicable local design requirements.

What should an importer provide for a heat detector enquiry?

Provide the country, application, ambient conditions, ceiling height, quantity, local-only or remote reporting requirement, packaging language and required evidence.

Can one WANLIN-340 specification cover every radio version?

No. Communication module, platform, label, power arrangement and evidence can vary. Confirm the controlled configuration before quotation or a formal claim.

Does the manual prove export certification?

No. A product manual records operating and installation information; it is not a third-party certificate and does not establish destination-market acceptance.

Request a model-specific heat detector review

Send the country, application, ambient conditions, quantity, reporting method and evidence requirements to wanlinfirecontrol@163.com.

Last reviewed: 2026-11-02. No local office is claimed; Wanlin Fire manufactures in Shenzhen, China and supports export enquiries.